CNT-90XL
Microwave Frequency Counter/Analyzer

  • Category: Microwave Frequency Counter/Analyzer
  • Manufacturer: Pendulum Instruments
  • Input C frequency range: 0.3 to 27, 40, 46 or 60 GHz (depending on model)
  • General-purpose input A, B frequency range: 0.002 Hz to 400 MHz
  • Measurement speed: 250k measurements/s (to internal memory)
  • Frequency resolution: 12 digits/s (1 s measuring time)
  • Data sheet: Download PDF
  • External link: Official product page

Overview

The CNT-90XL microwave counter/analyzer sets a new industry standard for microwave frequency analysis, outperforming any pulsed or CW microwave counter on the market in resolution, speed and acquisition time. Input C covers 0.3 to 27, 40, 46 or 60 GHz depending on the model, and the measurement speed reaches 250,000 frequency samples per second, enough for advanced statistical analysis and for frequency or power transient analysis. For the resolution that R&D and production test demand, the CNT-90XL offers 100 ps single shot (time) or 12 digits/s (frequency), with values displayed to up to 14 digits. The optional pulsed RF function (Option 28) measures pulses down to 30 ns wide, plus PRI/PRF, frequency in burst and power in burst, which makes it ideal for testing and calibrating pulsed, chirped and Doppler radar. A graphical display and menu-oriented settings let a non-expert make the right settings without risking costly mistakes; USB and GPIB are standard, and the GPIB operates in either SCPI/GPIB or 53131 emulation mode for plug-and-play replacement in an existing ATE system.

Key features

  • The fastest microwave counter — Up to 250,000 frequency samples per second, with an acquisition time of only 25 ms in Auto mode, for real-time analysis of frequency and power transients.
  • Pulsed RF measurements (optional) — Option 28 measures pulses down to 30 ns wide, plus PRI/PRF, frequency in burst and power in burst — the right tool for radar test and calibration.
  • High resolution and accuracy — 100 ps single shot (time) or 12 digits/s (frequency), displayed to up to 14 digits, against a stable internal OCXO timebase.
  • Statistical and graphical analysis — Histogram, trend and modulation domain displays let you view one data set three ways at once — numerically, as a histogram and as a trend — to see jitter and drift for what they are.
  • Two instruments in one — A microwave counter/analyzer and a 400 MHz general-purpose timer/counter in the same box, which saves a second instrument in production test.
  • USB and GPIB as standard — USB and GPIB are fitted as standard, and the GPIB operates in either SCPI/GPIB or 53131 emulation mode for plug-and-play replacement in an existing ATE system.

Typical applications

  • Pulsed and Doppler radar signal analysis — Radar development and maintenance verification need exact figures for pulse width (down to 30 ns), PRI/PRF and the Doppler shift the carrier picks up from a moving target. The CNT-90XL shows the frequency trend and the power distribution histogram live, so one instrument does the signal characterization that used to take an oscilloscope and a spectrum analyzer together.
  • Factory calibration of microwave link carriers and RF components — Metrology laboratories and production floors calibrating YIG oscillators, VCO modules and microwave link transmitters rely on the CNT-90XL's 12 digits/s frequency resolution and internal OCXO timebase for traceable accuracy. The GPIB supports 53131 emulation mode, so it slots into an existing ATE line and shortens changeover time.
  • Field testing at satellite ground stations and off-grid sites — Commissioning a satellite ground station, or testing at a remote site with no mains power, the CNT-90XL runs for more than 4.5 hours on the optional 90 Wh battery pack. The 24-hour battery stand-by also lets an engineer move a high-stability oscillator without losing its thermal state, so measurement can begin on arrival and site time is cut sharply.

Key specifications

Key specifications for CNT-90XL, as published by Pendulum Instruments. For the full datasheet or a customized configuration, please get in touch.

Input C frequency range0.3 to 27, 40, 46 or 60 GHz (depending on model)
General-purpose input A, B frequency range0.002 Hz to 400 MHz
Measurement speed250k measurements/s (to internal memory)
Frequency resolution12 digits/s (1 s measuring time)
Single-shot time resolution100 ps
Displayed digitsUp to 14 digits
Input C sensitivity-33 dBm (0.3 to 18 GHz)
Power measurement range-35 dBm to +10 dBm
Power accuracy (typical)<1 dBm to 27 GHz; <2 dBm to 40 GHz; <3 dBm to 60 GHz
Pulsed RF pulse width (Option 28)30 ns to 1 sec., resolution 200 ps rms
Timebase stability (optional)Option 30/90: 0.01 ppm/month; Option 40/90: 0.003 ppm/month
InterfacesUSB and GPIB (standard)

Options and configuration

Tick the options you need and we will collect the configuration and carry it into the inquiry form.

Standard equipment (included)

Microwave frequency counting/analysis mainframeThe CNT-90XL itself, with interpolating reciprocal counting, 12 digits/s frequency resolution and 100 ps single-shot time resolution
Medium stability OCXO reference oscillatorMedium Stability OCXO timebase fitted as standard, for general measurement work
400 MHz general-purpose timer/counter inputAn integrated 400 MHz general-purpose timer/counter channel on the front panel, measuring frequency, period, time interval, phase, duty cycle, rise/fall time and peak voltage
GPIB + USB interfacesGPIB and USB remote control interfaces fitted as standard, with 250k readings/s into data memory
Line cord, calibration certificate, documentation CDSupplied with a line cord, a factory Certificate of Calibration and a CD carrying the Getting Started Manual, User's Manual and Programmer's Handbook as PDFs

Hardware options

Software options / Option

0 options selected Standard configuration only
Add this configuration to an inquiry

Frequently asked questions

Yes. KanTek Technology is the authorized Taiwan distributor for Pendulum Instruments, supplying new CNT-90XL instruments with factory quotations and technical advice.

Instrument rental is launching soon. CNT-90XL is part of the line-up being prepared, and advance enquiries are welcome.

Yes. KanTek provides calibration and repair for CNT-90XL, with calibration performed by a partner laboratory, to keep the instrument accurate and available.

Use Request a quote on this page, or call +886-2-2999-7719. KanTek replies within 24 hours with pricing, lead time and the options that suit your application.
Authorized Pendulum distributor
Repair and calibration services
Instrument rental, launching soon
Reply within 24 hours

Need CNT-90XL pricing, rental or calibration?

Request a quote