R&S® RT-ZM modular probe system
Modular probe system (1.5 GHz to 16 GHz, interchangeable tip modules)
- Category: Oscilloscope probe
- Manufacturer: Rohde & Schwarz
- Bandwidth (RT-ZM15): >1.5 GHz
- Bandwidth (RT-ZM30): >3 GHz
- Bandwidth (RT-ZM60): >6 GHz
- Bandwidth (RT-ZM90): >9 GHz
- Bandwidth (RT-ZM130): >13 GHz
- Bandwidth (RT-ZM160): >16 GHz
- Rise time (RT-ZM15): <230 ps
- Rise time (RT-ZM30): <100 ps
- Rise time (RT-ZM60): <75 ps
- Rise time (RT-ZM90): <50 ps
- Rise time (RT-ZM130): <35 ps
- Rise time (RT-ZM160): <28 ps
- DC offset compensation range: ±16 V
- ProbeMeter DC measurement accuracy: 0.05 %
- Measurement modes: Single-ended (P) / negative (N) / differential (DM) / common mode (CM)
- Capacitive loading: Low capacitive load
- Compatible oscilloscopes: R&S® RTP, R&S® RTO6, R&S® MXO 5
- Data sheet: Download PDF
- Product brochure: Download PDF
- External link: Official product page
Overview
The R&S® RT-ZM modular probe system answers today's high-speed probing challenges with a technically precise solution that is still straightforward to use. Every probing arrangement combines high bandwidth and a wide dynamic range while keeping capacitive loading low. The system pairs tip modules for a range of measurement tasks and conditions (the RT-ZMA family) with amplifier modules from 1.5 GHz to 16 GHz. A dedicated ASIC supports single-ended, differential and common mode measurement and switches between them without reconnecting or re-soldering, offers ±16 V of DC offset compensation, and includes a high-precision voltmeter (R&S® ProbeMeter) that measures DC voltage to 0.05 % accuracy independently of the oscilloscope.
Key features
- Flexible and configurable connectivity: the modular design accepts solder-in, quick-connect, SMA and flexible tip modules, so it suits almost any measurement setup and board layout.
- Multimode measurement: a dedicated high-speed ASIC switches between single-ended (P/N), differential (DM) and common mode (CM) measurement on the fly, with no reconnecting and no re-soldering of the tip.
- ±16 V DC offset compensation: applied at the tip, upstream of the differential ASIC, it cancels the DC component of the signal, opening a measurement window beyond the amplifier's dynamic range and showing the part of the signal you care about at full resolution.
- Integrated high-precision voltmeter (R&S® ProbeMeter): runs independently of the oscilloscope, measuring the DC component continuously to 0.05 % accuracy in parallel with waveform acquisition, digitised in real time by a dedicated ADC inside the amplifier module.
- Micro button control: the micro button on the amplifier module can be assigned to run/stop, auto set, save waveform, set trigger level, generate an automated test report or switch measurement mode, so the oscilloscope can be driven without looking away from the probe.
- Low capacitive loading: every tip module presents a low capacitive load, reducing the effect on the circuit under test and keeping high-speed measurements honest.
- The RT-ZMA1 hard storage case carries up to six RT-ZMA tip cables, for transport and use on site.
Typical applications
- Differential probing of high-speed serial interfaces (PCIe, USB, DDR, SerDes)
- Multi-channel power integrity measurement
- Common mode noise analysis on differential signals
- Signal integrity measurement on high-speed digital circuits
- Circuit characterisation over temperature (with the RT-ZMA11 / RT-ZMA50)
- High-bandwidth single-ended measurement on RF and microwave circuits (with the RT-ZMA40 SMA module)
- High-accuracy DC offset measurement in aerospace, defence and telecommunications systems
Configure your R&S® RT-ZM Modular Probe System
Pick a base model and its options, watch your order list build as you go, then send it for a quote in one click. Every order number (Order No.) comes from Rohde & Schwarz factory data.
Hardware options
6 optionsProbes
9 optionsAccessories
5 optionsAvailable models / variants
The system comprises the 15 variants below. Click "Request a quote" for full specifications and pricing on a given model from KanTek.
| Model | Differences | |
|---|---|---|
| R&S® RT-ZM15 (1800.4700.02) | Request a quote → | |
| R&S® RT-ZM30 (1419.3005.02) | Request a quote → | |
| R&S® RT-ZM60 (1419.3105.02) | Request a quote → | |
| R&S® RT-ZM90 (1419.3205.02) | Request a quote → | |
| R&S® RT-ZM130 (1800.4500.02) | Request a quote → | |
| R&S® RT-ZM160 (1800.4600.02) | Request a quote → | |
| R&S® RT-ZMA10 (1419.4301.02) | Request a quote → | |
| R&S® RT-ZMA10-6 (1801.4349.02) | Request a quote → | |
| R&S® RT-ZMA11 (1419.4318.02) | Request a quote → | |
| R&S® RT-ZMA12 (1419.4324.02) | Request a quote → | |
| R&S® RT-ZMA14 (1338.1010.02) | Request a quote → | |
| R&S® RT-ZMA15 (1419.4224.02) | Request a quote → | |
| R&S® RT-ZMA30 (1419.4353.02) | Request a quote → | |
| R&S® RT-ZMA40 (1419.4201.02) | Request a quote → | |
| R&S® RT-ZMA50 (1419.4218.02) | Request a quote → |