R&S®HZ-15 EMC near-field probe set
EMC near-field probe set (30 MHz to 3 GHz, E-field and H-field probes)
- Category: Oscilloscope probe
- Manufacturer: Rohde & Schwarz
- Frequency range (probe set): 30 MHz – 3 GHz
- Probe types: 2 passive E-field probes + 3 passive H-field probes
- H-field probe characteristics: Electrically shielded magnetic field probes, passive (no supply needed)
- E-field probe characteristics: Passive electric field probes for near-field measurement
- H-field antenna factor (typ. at 30 MHz): 50 dB [(µA/m)/µV]
- H-field antenna factor (typ. at 100 MHz): 40 dB [(µA/m)/µV]
- H-field antenna factor (typ. at 500 MHz): 28 dB [(µA/m)/µV]
- H-field antenna factor (typ. at 1000 MHz): 23 dB [(µA/m)/µV]
- Preamplifier gain (optional HZ-16): 20 dB (typical, 100 kHz to 3 GHz)
- Preamplifier frequency range (HZ-16): 100 kHz – 3 GHz
- Preamplifier 1 dB compression point: +8 dBm (typical)
- Preamplifier maximum input level: +10 dBm
- Spatial resolution: High spatial resolution (probe tips shaped for near-field work)
- EMI immunity testing: The H-field probes are bidirectional, so a signal can be injected for localised immunity testing
- Data sheet: Download PDF
- Product brochure: Download PDF
- External link: Official product page
Overview
The R&S®HZ-15 EMC near-field probe set covers E-field and H-field near-field measurement from 30 MHz to 3 GHz alongside an oscilloscope. The set holds two passive electric field probes and three electrically shielded passive magnetic field probes, which connect directly to an oscilloscope, a spectrum analyzer or a measuring receiver. The optional R&S®HZ-16 preamplifier adds 20 dB of gain and lifts sensitivity considerably on weak signals. The electrical shielding keeps E-field coupling out of the H-field measurement, and the probe tips are shaped for near-field work, giving the spatial resolution needed to pin down the source of an EMI problem. Being passive and bidirectional, the H-field probes can also inject a signal for localised immunity testing.
Key features
- Wide frequency range, 30 MHz to 3 GHz, covering the usual EMI trouble bands
- A complete set: 2 E-field probes plus 3 H-field probes in different sizes for different measurement needs
- Electrically shielded magnetic field probes suppress electric field coupling, so the H-field reading stays honest
- High spatial resolution: tips shaped for near-field measurement pinpoint the source of interference
- Bidirectional H-field probes inject a signal for localised immunity testing (local current injection)
- Simple to use: connects to oscilloscopes, spectrum analyzers and measuring receivers
- Optional HZ-16 preamplifier: 20 dB gain (100 kHz to 3 GHz) for weak-signal work, 1 dB compression point +8 dBm
- Broad compatibility: the HZ-16 works with both the R&S®HZ-15 and the R&S®HZ-17 probe set
Typical applications
- EMI debugging and interference source location: finding radiation hot spots while the board is still on the bench
- Near-field scanning: mapping local E-field and H-field distribution on a PCB to study signal integrity
- EMC pre-compliance: quick debugging before formal certification testing, shortening the development cycle
- Localised immunity testing: injecting interference into a specific area of a circuit with the bidirectional H-field probes
- Use with R&S oscilloscopes such as the RTM3000, RTA4000 and RTO2000 for time-domain EMI analysis
- Use with spectrum analyzers and EMI test receivers such as the R&S FPC, FSH, ESR, ESRP and ESW
Configure your R&S®HZ-15 EMC Near-field Probe Set
Pick a base model and its options, watch your order list build as you go, then send it for a quote in one click. Every order number (Order No.) comes from Rohde & Schwarz factory data.
Hardware options
1 optionProbes
1 optionAvailable models / variants
The range comprises the 3 variants below. Click "Request a quote" for full specifications and pricing on a given model from KanTek.
| Model | Differences | |
|---|---|---|
| R&S®HZ-15 (1147.2736.02) | Complete EMC near-field probe set: 2 passive E-field probes and 3 passive, electrically shielded H-field probes, 30 MHz to 3 GHz. The R&S®HZ-16 preamplifier is available as an option. | Request a quote → |
| R&S®HZ-16 (1147.2720.02) | Preamplifier for the near-field probes, 100 kHz to 3 GHz, 20 dB gain. Works with both the R&S®HZ-15 and R&S®HZ-17 sets and lifts sensitivity on weak signals. | Request a quote → |
| R&S®HZ-17 (1339.4141.02) | H-field near-field probe set: 2 passive magnetic field probes, 30 MHz to 3 GHz, for magnetic-field-only work. The R&S®HZ-16 preamplifier is available as an option. | Request a quote → |
Frequently asked questions
Need R&S®HZ-15 EMC Near-field Probe Set pricing, rental or calibration?