R&S®ATS1800C
Compact 3GPP-compliant OTA chamber (5G NR FR2 mmWave, CATR)

  • Category: Antenna test systems and OTA chambers
  • Manufacturer: Rohde & Schwarz
  • Frequency range (in-band): 23.5 GHz to 44.3 GHz (meas.)
  • Frequency range (out-of-band, OOB): 6 GHz to 170 GHz
  • Shielding effectiveness: > 90 dB (meas.)
  • Feed antenna polarization: Dual polarized
  • RF connectors (feed H/V): 2 × PC 1.85 mm (f)
  • RF connector (link / DUT): 1 × PC 1.85 mm (f)
  • Quiet zone size (standard reflector CATR-REFL1): Ø 30 cm
  • Quiet zone size (large reflector CATR-REFL6): Ø 40 cm
  • Amplitude performance — average amplitude taper: < 1.5 dB (meas.)
  • Amplitude performance — average amplitude ripple: < 0.5 dB (meas.)
  • Phase deviation (28 GHz): ±7.5° (meas.)
  • Phase deviation (39 GHz): ±10° (meas.)
  • Path loss (28 GHz): < 51 dB
  • Path loss (39 GHz): < 53 dB
  • Power supply: 100 V to 120 V / 200 V to 240 V (AC), 50 Hz to 60 Hz, max. 5 A
  • Weight: approx. 500 kg (1102.31 lb)
  • Overall dimensions (W x H x D): 0.90 m × 1.99 m × 1.53 m (35.43 in × 78.35 in × 60.24 in)
  • Castors: 4
  • Data sheet: Download PDF
  • Product brochure: Download PDF
  • External link: Official product page

Product overview

The R&S®ATS1800C is a chamber based on compact antenna test range (CATR) technology, designed for over-the-air (OTA) measurement of 5G NR FR2 mmWave antennas, modules and devices across the full lifecycle from development to 3GPP regulatory conformance testing. Its small 1.3 m² footprint and castor base let it be moved easily and pass through a standard doorway, while it still offers a wide frequency range up to 170 GHz and more than 90 dB of shielding effectiveness. A high-precision bidirectional parabolic CATR reflector, a 3D positioner with hardware triggering and an automatic feed switcher make it one of the most complete 5G mmWave OTA test platforms available; it is fully 3GPP compliant and supports CTIA FR2 antenna performance testing and extension to multiple angles of arrival (RRM) testing.

Key features

  • 3GPP-compliant, transportable CATR test chamber for the FR2 band (5G NR FR2)
  • Wide frequency coverage: 23.5 GHz to 44.3 GHz in band, up to 170 GHz out of band
  • Quiet zone up to 40 cm in diameter (with the large CATR-REFL6 reflector) in a footprint of only about 1.3 m²
  • Shielding effectiveness > 90 dB (meas.), keeping the test environment interference-free
  • State-of-the-art bidirectional parabolic CATR reflector with optimized rolled edges and a surface roughness < 1 μm RMS, for uniform power distribution across the quiet zone
  • Spherical 3D positioner with built-in hardware triggering (azimuth ± 181°, trigger accuracy < 0.01°), which shortens test times considerably
  • Automatic feed switcher for up to 4 feed antennas with a switching time < 5 s, giving seamless wideband coverage
  • Optional extreme temperature module (CATR-TEMP2) for 3D radiated measurement from -40 °C to +85 °C
  • Supports multiple angle of arrival (AoA) testing, with left and right side chamber extensions (R&S®ATS1800M) for RRM test requirements
  • Optional infrared thermal imaging camera (CATR-CAM1) for remote monitoring of heat dissipation on the device under test
  • Integrated USB 3.2 hub and Ethernet switch keep the device under test reliably connected

Typical applications

  • OTA measurement of 5G NR FR2 antennas, modules and devices (TRP, EIRP, EIS)
  • Antenna performance testing of smartphones, laptops and small cells
  • CTIA FR2 antenna performance testing (including phantom head and hand)
  • Out-of-band (OOB) emissions and radio resource management (RRM) testing
  • Beamforming characterization and device design validation (R&D)
  • 3GPP conformance testing
  • 3D radiated measurement at temperature extremes (-40 °C to +85 °C)
  • Multiple angle of arrival (AoA) and handover scenario simulation
Configurator

Configure your R&S®ATS1800C

Pick a base model and its options, watch your order list build as you go, then send it for a quote in one click. Every order number (Order No.) comes from Rohde & Schwarz factory data.

1

Base model

1 model
1 / 6
2

Hardware options

13 options
2 / 6
3

Software options (K-options)

1 option
3 / 6
4

Probes

6 options
4 / 6
5

PC software

1 option
5 / 6
6

Accessories

24 options
6 / 6

Available models / variants

This series comes in the following 2 variants. Click “Request a quote” to ask KanTek for the full specifications and pricing of the model you need.

Model codeSpecification differences
R&S®ATS1800C (1534.1800K03)CATR compact 5G NR mmWave test chamber (complete bundle)Request a quote →
R&S®ATS1800C (1534.1800.03)CATR compact 5G NR mmWave test chamber (base model)Request a quote →

Options / accessories

R&S®CATR-REFL1 (1534.2307.02) CATR reflector, standard size (Ø 30 cm quiet zone, 6–92 GHz)
R&S®CATR-REFL6 (1540.6500.02) CATR reflector, large size (Ø 40 cm quiet zone, 6–92 GHz)
R&S®CATR-TEMP2 (1534.2620.03) Extreme temperature conditions module (-40 °C to +85 °C, max. load 10 kg)
R&S®CATR-MNT2 (1540.6681.02) Rear mounting kit for RRH and RF42 equipment
R&S®CATR-CAM1 (1534.2471.03) Camera option combining visible light and infrared thermal imaging (accuracy ±2 °C)
R&S®CATR-HFIX1 (1534.2920.03) Phantom head or large DUT fixture (max. 20 kg, 3GPP alignment option 2)
R&S®CATR-MIMOA (1538.8880.02) 4x4 MIMO anchor antennas (2 dual polarized antennas)
R&S®CATR-RFRJ2 ((on request)) Dual RF rotary joint extension mounted on the azimuth axis (DC–50 GHz / DC–18 GHz)
R&S®CATR-FESWA (1540.6600.02) Automatic feed switcher (up to 4 antennas, switching < 5 s)
R&S®CATR-SCML1 (1540.6381.02) Left side chamber extension for multiple angle of arrival testing (includes 1 reflector)
R&S®CATR-SCMR2 (1540.6481.02) Right side chamber extension for multiple angle of arrival testing (includes 2 reflectors)
R&S®TS-F1U3BA1 (1537.6632.02) USB 3.2 B-type feedthrough connector
R&S®TS-F1U3CC1 (1537.6649.02) USB 3.2 C-type feedthrough connector
R&S®ATS1800C (built-in controller) (—) Built-in controller with an Ethernet web interface and API (C / C++ / C# / VB.NET / MATLAB®)
R&S®CATR-FE4 (1540.6223.02) OOB feed horn antenna (6–25 GHz, dual polarized)
R&S®CATR-FE30 (1540.6230.02) Feed horn antenna (6–35 GHz, dual polarized)
R&S®CATR-FE40 (1540.6246.02) Feed antenna with OMT (23.5–44.3 GHz, dual polarized, standard configuration)
R&S®CATR-FE60 (1540.6275.02) Feed antenna with OMT (36.5–61 GHz, dual polarized)
R&S®CATR-FE90 (1540.6269.02) Feed antenna with OMT (59–92 GHz, dual polarized)
R&S®TC-TA50CPR (1531.8633.02) Ruggedized Vivaldi link antenna (650 MHz–50 GHz, MMPX connector)
R&S®TS-QOQZIB (1545.4941.02) In-band quiet zone quality assessment fixture kit (supports TS 38.521-2 and CTIA 01.73)
R&S®CATR-FX40 (1540.6346.02) Fixed feed fixture for the CATR-FE40
R&S®CATR-FX4 ((on request)) Fixed feed fixture for the CATR-FE4
R&S®CATR-FX30 (1540.6330.02) Fixed feed fixture for the CATR-FE30
R&S®CATR-FX60 (1540.6375.02) Fixed feed fixture for the CATR-FE60
R&S®CATR-FX90 (1540.6369.02) Fixed feed fixture for the CATR-FE90
R&S®CATR-FL4 (1540.6423.02) Automatic switcher feed fixture for the CATR-FE4
R&S®CATR-FL30 (1540.6430.02) Automatic switcher feed fixture for the CATR-FE30
R&S®CATR-FL40 (1540.6446.02) Automatic switcher feed fixture for the CATR-FE40
R&S®CATR-FL60 (1540.6475.02) Automatic switcher feed fixture for the CATR-FE60
R&S®CATR-FL90 (1540.6469.02) Automatic switcher feed fixture for the CATR-FE90
R&S®CATR-FM4 (1540.6617.02) Side chamber feed fixture for the CATR-FE4
R&S®CATR-FM30 (1540.6623.02) Side chamber feed fixture for the CATR-FE30
R&S®CATR-FM40 (1540.6630.02) Side chamber feed fixture for the CATR-FE40
R&S®CATR-FM60 (1540.6675.02) Side chamber feed fixture for the CATR-FE60
R&S®CATR-FM90 (1540.6652.02) Side chamber feed fixture for the CATR-FE90
R&S®CATR-FIX1U (1540.6317.02) Fixture for 3GPP alignment options 1 and 3
R&S®CATR-FIX2U (1540.6300.02) Fixture for 3GPP alignment option 2
R&S®TC-SGH40 (1530.8617.02) Standard gain horn antenna for calibration, 26.5 GHz – 40 GHz
R&S®TC-SGH60M (1536.8590.02) Calibration / alignment antenna (40–60 GHz)
R&S®TC-SGH90M (1536.8454.02) Calibration / alignment antenna (60–90 GHz)
R&S®NRP50S (1419.0087.02) Three-path diode power sensor
R&S®NRP-ZKU (1419.0658.05) USB power sensor cable (5 m)
R&S®ATS-C50MF (1535.7977.02) 50 GHz coaxial cable (1.2 m, 1.85 mm m to f)
R&S®ATS-C50MM3 (3658.4232.02) 50 GHz coaxial cable (0.3 m, 2.4 mm m to m)

Frequently asked questions

Yes. KanTek Technology is the authorized Taiwan distributor for Rohde & Schwarz, supplying new R&S®ATS1800C instruments with factory quotations and technical advice.

Instrument rental is launching soon. R&S®ATS1800C is part of the line-up being prepared, and advance enquiries are welcome.

Yes. KanTek provides calibration and repair for R&S®ATS1800C, with calibration performed by a partner laboratory, to keep the instrument accurate and available.

Use Request a quote on this page, or call +886-2-2999-7719. KanTek replies within 24 hours with pricing, lead time and the options that suit your application.

R&S®ATS1800C is a Rohde & Schwarz product: Compact 3GPP-compliant OTA chamber (5G NR FR2 millimeterwave, CATR). Contact KanTek for selection or application advice.
Authorized R&S distributor
Repair and calibration services
Instrument rental, launching soon
Reply within 24 hours

Need R&S®ATS1800C pricing, rental or calibration?

Request a quote